SERVICES

AGNITAR: Global Fire Protection Solutions.
Our Professional Services
At AGNITAR, we deliver not only advanced fire suppression systems but also a full scope of services — from fire suppression proposals, project design, and specifications to installation, commissioning, and long-term maintenance.
1. Project Design & Engineering
- Complete fire suppression project design compliant with NFPA 2001, ISO 14520, EN 15004
- Specialized design for FM-200 (HFC-227ea), FK-5-1-12 (Novec 1230), Inert gases (IG-541, IG-55, IG-100, IG-01), and CO2 systems
- Ready-to-use technical specifications and documentation for consultants and contractors
2. Hydraulic Calculations
- VdS-certified hydraulic flow calculations for clean agent, inert, and CO2 systems
- Optimized nozzle placement, pipe sizing, and cylinder quantity
- Ensures efficiency and compliance for Novec 1230, FM-200, CO2, and Inert fire suppression systems
3. Technical Specification Drafting & Pricing
- Preparation of detailed fire system specifications for tenders and project approvals
- Pricing support for contractors and investors with accurate cost analysis
- Professional assistance for fire suppression proposals and bidding
4. Material Supply
- Cylinders, valves, nozzles, actuators, detection units, and control panels
- Globally certified equipment: UL, FM, VdS, LPCB, CE, TPED
- Fast spare parts delivery to keep fire protection systems operational
5. System Installation & Commissioning
- Turnkey installation of FM-200, Novec 1230, Inert, and CO2 fire suppression systems
- Commissioning and full functional testing supervised by AGNITAR engineers and technical team.
- Delivered ready-for-use with compliance certificates
6. Service & Maintenance
- Scheduled inspections every 6 months by AGNITAR-authorized teams
- Preventive servicing and repairs for long-term reliability
- 10-year warranty against manufacturing defects when maintained by AGNITAR.
7. User & Technical Training
- User Training: Practical instruction for operators and facility staff on correct system use after commissioning
- Technical Training: Specialized training for installation and assembly teams to ensure proper and safe setup
- Covers operation and maintenance of fire suppression systems
8. Hydrostatic Testing
- Hydrostatic pressure tests for suppression cylinders
- Conducted by certified laboratories in compliance with TPED, PED, and CE directives
- Ensures cylinder safety and system reliability for FM-200, Novec 1230, CO2, and Inert gases
9. Room Integrity Test – Door Fan Test
- NFPA and ISO-compliant airtightness testing
- Verifies clean agent and inert gas retention time in protected rooms
- Essential for data centers, archives, control rooms, and industrial facilities
Why Choose Agnitar Services?
- End-to-end fire protection services: from fire suppression project design to installation and maintenance
- Specialized expertise in FM-200, Novec 1230, Inert (IG-541, IG-55, IG-100, IG-01) and CO2 systems
- Fully compliant with UL, FM, VdS, LPCB, CE, TPED international standards
- Trusted worldwide for fire suppression proposals, fire project design, and technical specifications