{"product_id":"agnitar-co2-fire-suppression-systems","title":"AGNITAR CO2 Fire Suppression Systems | Carbon Dioxide","description":"\u003ch2 data-start=\"630\" data-end=\"921\"\u003e\u003cstrong data-start=\"630\" data-end=\"670\"\u003eAGNITAR CO2 Fire Suppression Systems offer fast, clean, and high-pressure protection. Ideal for local and total flooding systems. TPED and VdS certified. Optional weighing device for safety monitoring.\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-end=\"916\" data-start=\"585\"\u003e\u003cstrong data-end=\"625\" data-start=\"585\"\u003eAGNITAR CO2 Fire Suppression Systems\u003c\/strong\u003e deliver \u003cstrong data-end=\"682\" data-start=\"634\"\u003ehigh-pressure, fast-acting, and residue-free\u003c\/strong\u003e fire protection using Carbon Dioxide (CO2). Designed for industrial and electrical applications, this system offers \u003cstrong data-end=\"852\" data-start=\"799\"\u003eboth local application and total flooding options\u003c\/strong\u003e, and supports \u003cstrong data-end=\"892\" data-start=\"867\"\u003emulti-room protection\u003c\/strong\u003e via directional valves.\u003c\/p\u003e\n\u003cp data-end=\"1203\" data-start=\"918\"\u003eCO₂ suppresses fire by \u003cstrong data-end=\"981\" data-start=\"941\"\u003edisplacing oxygen and absorbing heat\u003c\/strong\u003e, making it an excellent solution for \u003cstrong data-end=\"1052\" data-start=\"1019\"\u003enon-occupied, high-risk areas\u003c\/strong\u003e. As a \u003cstrong data-end=\"1077\" data-start=\"1059\"\u003enon-conductive\u003c\/strong\u003e, \u003cstrong data-end=\"1096\" data-start=\"1079\"\u003enon-corrosive\u003c\/strong\u003e, and \u003cstrong data-end=\"1115\" data-start=\"1102\"\u003enon-toxic\u003c\/strong\u003e extinguishing agent, it is \u003cstrong data-end=\"1202\" data-start=\"1143\"\u003esafe for use around electronics and sensitive equipment\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-end=\"1522\" data-start=\"1205\"\u003eAGNITAR's system also includes an optional \u003cstrong data-end=\"1267\" data-start=\"1239\"\u003eWeighing Device\u003c\/strong\u003e, which provides real-time monitoring of cylinder pressure through a spring-loaded mechanical system with built-in contact for alarm activation. This feature enhances \u003cstrong data-end=\"1471\" data-start=\"1434\"\u003esafety and maintenance efficiency\u003c\/strong\u003e, ensuring the system is always ready to discharge.\u003c\/p\u003e\n\u003ch3 data-start=\"1435\" data-end=\"1471\"\u003eCertifications \u0026amp; Compliance\u003c\/h3\u003e\n\u003cp data-start=\"1472\" data-end=\"1533\"\u003eAGNITAR systems use components that are globally certified:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1536\" data-end=\"1565\"\u003e\u003cstrong data-start=\"1536\" data-end=\"1563\"\u003eTPED Approved Cylinders\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1568\" data-end=\"1628\"\u003e\u003cstrong data-start=\"1568\" data-end=\"1626\"\u003eVdS Approved Valve Groups, Nozzles, and Flexible Hoses, Hydraulic Calculations\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"1631\" data-end=\"1704\"\u003eDesigned in accordance with \u003cstrong data-start=\"1659\" data-end=\"1670\"\u003eNFPA 12\u003c\/strong\u003e, \u003cstrong data-start=\"1672\" data-end=\"1684\"\u003eISO 6183\u003c\/strong\u003e, and \u003cstrong data-start=\"1690\" data-end=\"1702\"\u003eEN 12094\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1707\" data-end=\"1857\"\u003eCertifications such as \u003cstrong data-start=\"1730\" data-end=\"1755\"\u003eUL, FM, VdS, and LPCB\u003c\/strong\u003e are globally recognized in system components and should be considered in all compliant installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1864\" data-end=\"1885\"\u003eKey Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"1888\" data-end=\"1955\"\u003eHigh-pressure system allows long-distance installation\u003c\/li\u003e\n\u003cli data-start=\"1958\" data-end=\"2016\"\u003eNon-toxic and non-corrosive – safe for people-free zones\u003c\/li\u003e\n\u003cli data-start=\"2019\" data-end=\"2076\"\u003eNo residue – protects electronics and prevents downtime\u003c\/li\u003e\n\u003cli data-start=\"2079\" data-end=\"2142\"\u003eDirectional valve setups reduce costs in multi-room buildings\u003c\/li\u003e\n\u003cli data-start=\"2145\" data-end=\"2197\"\u003eSupports both total flooding and local application\u003c\/li\u003e\n\u003cli data-start=\"2200\" data-end=\"2261\"\u003eCertified system components ensure international compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2268\" data-end=\"2301\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"2304\" data-end=\"2337\"\u003e\n\u003cstrong data-start=\"2304\" data-end=\"2313\"\u003eAgent\u003c\/strong\u003e: Carbon Dioxide (CO2)\u003c\/li\u003e\n\u003cli data-start=\"2340\" data-end=\"2393\"\u003e\n\u003cstrong data-start=\"2340\" data-end=\"2355\"\u003eSystem Type\u003c\/strong\u003e: Total Flooding \/ Local Application\u003c\/li\u003e\n\u003cli data-start=\"2440\" data-end=\"2486\"\u003e\n\u003cstrong data-start=\"2440\" data-end=\"2453\"\u003eActuation\u003c\/strong\u003e: Electric \/ Pneumatic \/ Manual\u003c\/li\u003e\n\u003cli data-start=\"2489\" data-end=\"2528\"\u003e\n\u003cstrong data-start=\"2489\" data-end=\"2510\"\u003eTemperature Range\u003c\/strong\u003e: -20°C to +50°C\u003c\/li\u003e\n\u003cli data-start=\"2531\" data-end=\"2587\"\u003e\n\u003cstrong data-start=\"2531\" data-end=\"2551\"\u003eCylinder Options\u003c\/strong\u003e: 67L and above (custom available)\u003c\/li\u003e\n\u003cli data-start=\"2590\" data-end=\"2630\"\u003e\n\u003cstrong data-start=\"2590\" data-end=\"2608\"\u003eCertifications\u003c\/strong\u003e: TPED, VdS, EN, ISO, NFPA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2637\" data-end=\"2663\"\u003eApplication Areas\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-start=\"2666\" data-end=\"2711\"\u003eElectrical Rooms \u0026amp; Transformer Compartments\u003c\/li\u003e\n\u003cli data-start=\"2714\" data-end=\"2743\"\u003eData Centers \u0026amp; Server Rooms\u003c\/li\u003e\n\u003cli data-start=\"2746\" data-end=\"2767\"\u003eMarine Engine Rooms\u003c\/li\u003e\n\u003cli data-start=\"2770\" data-end=\"2806\"\u003ePaint Booths \u0026amp; Manufacturing Zones\u003c\/li\u003e\n\u003cli data-start=\"2809\" data-end=\"2839\"\u003eArchives, Museums, Libraries\u003c\/li\u003e\n\u003cli data-start=\"2842\" data-end=\"2876\"\u003eHazardous Material Storage Areas\u003c\/li\u003e\n\u003cli data-start=\"2879\" data-end=\"2910\"\u003eTurbine Rooms \u0026amp; Rolling Mills\u003c\/li\u003e\n\u003cli data-start=\"2913\" data-end=\"2946\"\u003eMulti-room Industrial Buildings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2953\" data-end=\"3007\"\u003eLocal Application – Targeted Fire Suppression\u003c\/h3\u003e\n\u003cp data-start=\"3008\" data-end=\"3217\"\u003e\u003cstrong data-start=\"3008\" data-end=\"3029\"\u003eAGNITAR's Local Application\u003c\/strong\u003e CO2 systems are designed to suppress fires \u003cstrong data-start=\"3073\" data-end=\"3099\"\u003eat the point of origin\u003c\/strong\u003e, without flooding the entire room. This method delivers the extinguishing agent directly to specific hazards such as:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"3221\" data-end=\"3237\"\u003eControl panels\u003c\/li\u003e\n\u003cli data-start=\"3240\" data-end=\"3262\"\u003eIndustrial machinery\u003c\/li\u003e\n\u003cli data-start=\"3265\" data-end=\"3286\"\u003eElectrical cabinets\u003c\/li\u003e\n\u003cli data-start=\"3289\" data-end=\"3322\"\u003ePaint lines\u003c\/li\u003e\n\u003cli data-start=\"3289\" data-end=\"3322\"\u003eCNC machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3324\" data-end=\"3709\"\u003eThis targeted approach reduces the amount of gas required and offers \u003cstrong data-start=\"3393\" data-end=\"3433\"\u003efaster suppression and less downtime\u003c\/strong\u003e, especially in facilities with \u003cstrong data-start=\"3465\" data-end=\"3497\"\u003enon-occupied machinery areas\u003c\/strong\u003e. AGNITAR's systems are designed for \u003cstrong data-start=\"3534\" data-end=\"3565\"\u003eflexible nozzle positioning\u003c\/strong\u003e and \u003cstrong data-start=\"3570\" data-end=\"3605\"\u003ecustom discharge configurations\u003c\/strong\u003e, ensuring maximum efficiency where full flooding is not necessary\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3 data-end=\"3447\" data-start=\"3387\"\u003e\u003cstrong data-end=\"3445\" data-start=\"3393\"\u003eWhy Choose Agnitar CO₂ Fire Suppression Systems?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-end=\"3519\" data-start=\"3450\"\u003e\n\u003cstrong data-end=\"3476\" data-start=\"3452\"\u003eHigh-Pressure Design\u003c\/strong\u003e: Effective even over long pipe distances\u003c\/li\u003e\n\u003cli data-end=\"3589\" data-start=\"3522\"\u003e\n\u003cstrong data-end=\"3558\" data-start=\"3524\"\u003eEconomical Multi-Zone Solution\u003c\/strong\u003e: Supports directional valves\u003c\/li\u003e\n\u003cli data-end=\"3643\" data-start=\"3592\"\u003e\n\u003cstrong data-end=\"3618\" data-start=\"3594\"\u003eCertified Components\u003c\/strong\u003e: TPED and VdS approved\u003c\/li\u003e\n\u003cli data-end=\"3707\" data-start=\"3646\"\u003e\n\u003cstrong data-end=\"3676\" data-start=\"3648\"\u003eOptional Weighing Device\u003c\/strong\u003e: Real-time safety monitoring\u003c\/li\u003e\n\u003cli data-end=\"3764\" data-start=\"3710\"\u003e\n\u003cstrong data-end=\"3726\" data-start=\"3712\"\u003eNo Residue\u003c\/strong\u003e: Zero damage to sensitive equipment\u003c\/li\u003e\n\u003cli data-end=\"3825\" data-start=\"3767\"\u003e\n\u003cstrong data-end=\"3801\" data-start=\"3769\"\u003eNon-Conductive\u003c\/strong\u003e: Safe for electronics\u003c\/li\u003e\n\u003cli data-end=\"3891\" data-start=\"3828\"\u003e\n\u003cstrong data-end=\"3856\" data-start=\"3830\"\u003eFlexible Configuration\u003c\/strong\u003e: Local or total flooding options\u003c\/li\u003e\n\u003cli data-end=\"3960\" data-start=\"3894\"\u003e\n\u003cstrong data-end=\"3930\" data-start=\"3896\"\u003eEngineered to Global Standards\u003c\/strong\u003e: Designed per NFPA, EN, ISO\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"AGNITAR | Manufacturer of Fire Suppression Systems","offers":[{"title":"Default Title","offer_id":41620584759381,"sku":"CO2","price":1.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0595\/9719\/3301\/files\/Agnitar_CO2_Fire_System_Weighing_Device.png?v=1754675214","url":"https:\/\/agnitar.com\/fa\/products\/agnitar-co2-fire-suppression-systems","provider":"AGNITAR | Manufacturer of Fire Suppression Systems","version":"1.0","type":"link"}